Ubiquiti U-Cable-C6-CMR CAT6 U/UTP Solid Ethernet Cable
Ubiquiti U-Cable-C6-CMR CAT6 U/UTP Solid Ethernet Cable
SKU:UC-C6-CMR
Out of stock
Ubiquiti U-Cable-C6-CMR CAT6 U/UTP Solid Ethernet Cable
Ubiquiti UniFi Cable / UC-C6-CMR - Indoor CAT6 Ethernet cable for use in high-speed UniFi and regular ethernet networks with data rates of up to 1 Gbps.
The UC-C6-CMR cable corresponds to the provisions of a CMR fire protection cable and is therefore also suitable for flush-mounted and floor-spanning / riser cabling.
CMR (Communications Multipurpose cable, Riser) cabling is flame-retardant and can be run vertically between floors in non-plenum areas.
Ubiquiti U-Cable-C6-CMR CAT6 U/UTP Solid Ethernet Cable, 305m, White, PVC (Boxed)
Ubiquiti U-Cable-C6-CMR CAT6 U/UTP Solid Ethernet Cable
Ubiquiti U-Cable-C6-CMR CAT6 U/UTP Solid Ethernet Cable supports speeds up to 1Gbps with its 23 AWG solid copper, twisted pair conductor.
The conductor's small diameter, combined with the cable's anti-crosstalk divider, isolates and protects signals from interference.
The U-Cable-C6-CMR is also a CMR cable with a fire-resistant jacket that ensures safe operation across multiple floors and vertical shafts. Category 6 Ethernet connectors are recommended to accommodate the conductor's size and optimize its performance.
Key Features
- Category 6 Unshielded Twisted Pair (UTP) cable.
- Communications Multipurpose Cable, Riser (CMR)-rated, fire-resistant jacket.
- Length: 305 m (1,000 ft.).
- 23 AWG solid copper, twisted pair conductor.
- Anti-crosstalk divider.
- For 1000BASE-T Ethernet applications.
Specifications
Mechanical
Box Dimensions
- 474 x 346 x 458 mm (18.7 x 13.6 x 18 in.)
Box Weight
- 14.83 kg (32.69 lb.)
Cable Length
- 305 m (1000 ft.)
Cable Colour
- White
Cable Type
- Category 6
Shielding Type
- UTP
Flame Rating
- CMR
Conductor Wire Gauge
- 23 AWG
Conductor Type
- Solid Bare Copper
Jacket Material
- PVC
Jacket Diameter
- 6.0 ± 0.2 mm
Bend Radius
- Min. 24 mm
Pulling Tension
- Max. 110 N
Storage Temperature
- -20°C to 75°C (-4°F to 167°F)
Installation Temperature
- 0°C to 60°C (32°F to 140°F)
Operation Temperature
- -20°C to 60°C (-4°F to 60°F)
Anti-Crosstalk Divider
- Yes
Ripcord
- Yes
Data Rate
- 10/100/1000 Base-T
Reference Bandwith
- Up to 600 MHz
Standards
- Electrical Transmission:
- ANSI/TIA-568-C.2 (2009)
- ISO/IEC 11801 (Edition 2.2)
- IEC 61156-5 (Edition 2.1)
- Flame Test:
- UL 1666 (CMR)
- Material and Construction:
- UL 444
- CSA 22.2 NO.214
- EU Directive 2011/65/EU (RoHS2)